This page is the permanent record for one lot of material: what was tested, by which laboratory, under which method, and what the report says. The report images below are the source documents.

Test summary

Test Compound Presentation Lot Date Laboratory Method Standard Result Criterion
Purity GHK-Cu 100mg V260123-1 2/10/2026 Vanguard Laboratory, A2LA cert 6377.01.01 HPLC-UV/VIS >99.80% Pass
Heavy metals GHK-Cu 100mg V260123-1 2/10/2026 Vanguard Laboratory, A2LA cert 6377.01.01 ICP-MS Arsenic=ND | Cadmium=ND | Lead=ND | Mercury=ND
Endotoxin GHK-Cu 100mg V260123-1 2/10/2026 Vanguard Laboratory, A2LA cert 6377.01.01 HPLC-UV/VIS USP <85> <5.00 EU/mg (limit 5.00) Pass

The reports

V260123-1 HPLC-UV/VIS report — GHK-Cu 100mg
Purity report page
V260123-1 ICP-MS report — GHK-Cu 100mg
Heavy metals report page

What these tests measure

Purity

A purity assay separates the sample on a reversed-phase HPLC column and reports the target peak as a percentage of total peak area.

It answers one analytical question only: how much of the material in the vial is the identified compound, and what else is present.

Heavy metals

Inductively coupled plasma mass spectrometry (ICP-MS) quantifies elemental impurities — typically lead, arsenic, cadmium and mercury — in parts per million or parts per billion.

It is a separate page of the same laboratory report and carries no purity or endotoxin figure of its own.

Endotoxin

A Limulus amebocyte lysate (LAL) assay measures bacterial endotoxin in the sample against the compendial procedure USP <85>, reported in endotoxin units per milligram (EU/mg).

The number is compared to the limit printed on the report; it describes the material, not any use of it.

Further reading: our testing methodology and the bench calculator.

Other records

Cite this record

Licensed Peptides, Lot V260123-1 test record (GHK-Cu 100mg), retrieved 13 September 2026, https://licensedpeptides.com/lab-reports/v260123-1-ghk-cu-100mg/.

Data on this page is published under CC BY 4.0. Reuse it, with attribution. Machine-readable copies: data.csv · data.json.

For laboratory research use only. Not for human or veterinary use.

You cannot copy content of this page